ck add signallogger

Adds a Signal Logger to the current measurement setup. Only one type of trigger can be used at a time for start and stop separately. The available triggers are: Timeout, Signal and Identifier.

Synopsis

ck add signallogger
    <SIGNAL_QUALIFIED_NAME>...
    [--url <String>]
    [--api-key <String>]
    [--language <en|zh|ja>]
    -p|--path <LOG_FILE_PATH>
    [-f|--format <LOG_FILE_FORMAT>]
    [-n|--name <NODE_NAME>]
    [--start-timeout <START_TIMEOUT_MS>]
    [--start-id <START_MESSAGE_ID>]
    [--start-source <START_MESSAGE_SOURCE>]
    [--stop-timeout <STOP_TIMEOUT_MS>]
    [--stop-id <STOP_MESSAGE_ID>]
    [--stop-source <STOP_MESSAGE_SOURCE>]
    [--auto-restart]
    [--skip-file-header]
    [--write-data-in-dec]
    [--write-id-in-dec]
    [--decimal-separator <DecDot|DecComma>]
    [--col-separator <Comma|Semicolon>]
    [--data-bytes-converter-limit <DATA_BYTES_CONVERTER_LIMIT>]
    [--size-limit <SIZE_LIMIT_MB>]
    [--data-decimals <NUMBER_OF_DATA_DECIMALS>]
    [--time-limit <TIME_LIMIT_S>]
    [--time-decimals <NUMBER_OF_TIME_DECIMALS>]
    [--use-calendar-time]
    [--use-local-time]
    [--time-reference <FirstTrigger|StartOfMeasurement>]
    [--start-signal-value <START_SIGNAL_VALUE>]
    [--stop-signal-value <STOP_SIGNAL_VALUE>]
    [--start-signal-qualified-name <START_SIGNAL_QUALIFIED_NAME>]
    [--stop-signal-qualified-name <STOP_SIGNAL_QUALIFIED_NAME>]
    [--start-operator <EqualTo|NotEqualTo|LessThan|LessThanOrEqual|GreaterThanOrEqual|GreaterThan|ChangeTo|ChangeFrom|OnChange>]
    [--stop-operator <EqualTo|NotEqualTo|LessThan|LessThanOrEqual|GreaterThanOrEqual|GreaterThan|ChangeTo|ChangeFrom|OnChange>]
    [--use-enum-values]
    [--write-fully-qualified-names]
    [--write-counter]
    [--write-units-on-own-row]
    [--write-data-frames]

ck add signallogger -h|--help

Arguments

  • SIGNAL_QUALIFIED_NAME
    Qualified names of the signals to log. Specify any source channel identifier or name if needed. Source channel is specified by preceding the signal name with the channel identifier or name followed by a slash (/).

Options

  • --url
    Specify the URL of the CanKingService if connecting to a remote host. Falls back to the CANKING_REMOTE_URL environment variable. If not specified, the command will connect to a local CanKingService instance.

  • --api-key
    API key required when connecting to a remote CanKingService instance. Falls back to the CANKING_REMOTE_API_KEY environment variable.

  • --language
    Specify the preferred language to be used in all output strings. Default value is English (en). Supported languages are English (en), Chinese (zh), and Japanese (ja).

  • -p|--path (required)
    Name of the file to log messages to, including full path.

  • -f|--format
    Format of the file to log messages to. If not given the format will be extracted from the path.

  • -n|--name
    Name of the node. Default value is ‘Signal Logger’

  • --start-timeout
    A timeout in milliseconds, to be used as start trigger.

  • --start-id
    The Message ID to use as start trigger. Prefix with 0x to indicate hex format.

  • --start-source
    The Message Source to use as start trigger, that is the identifier or name of the channel that sends/receives the trigger message.

  • --stop-timeout
    A timeout in milliseconds, to be used as stop trigger.

  • --stop-id
    The Message ID to use as stop trigger. Prefix with 0x to indicate hex format.

  • --stop-source
    The Message Source to use as stop trigger, that is the identifier or name of the channel that sends/receives the trigger message.

  • --auto-restart
    Automatically restart after stop.

  • --skip-file-header
    Skip writing file header

  • --write-data-in-dec
    Write data in decimal format.

  • --write-id-in-dec
    Write ID in decimal format.

  • --decimal-separator
    Use either a dot (DecDot) or comma (DecComma) as the decimal separator. Default value is a dot.

  • --col-separator
    Use either a comma or semicolon as the column separator. Default value is a comma.

  • --data-bytes-converter-limit
    Number of data bytes a converter will max write to the log file (1-64). Default value is 64.

  • --size-limit
    Max file size in megabytes before writing to a new file.

  • --data-decimals
    Number of data decimals (0-9). Default value is 4.

  • --time-limit
    Max number of seconds between first and last event before writing to a new file.

  • --time-decimals
    Number of time decimals (0-9). Default value is 9.

  • --use-calendar-time
    Write timestamps in calendar time instead of seconds.

  • --use-local-time
    Use local time instead of UTC for absolute timestamps.

  • --time-reference
    Use either first trigger or start of measurement as time reference. Default value is first trigger.

  • --start-signal-value
    The Signal Value to use as start trigger. Prefix with 0x to indicate hex format.

  • --stop-signal-value
    The Signal Value to use as stop trigger. Prefix with 0x to indicate hex format.

  • --start-signal-qualified-name
    The Signal Qualified Name to use as start.

  • --stop-signal-qualified-name
    The Signal Qualified Name to use as stop.

  • --start-operator
    The operator to use as start trigger. Default is 1 (EqualTo).

  • --stop-operator
    The operator to use as stop trigger. Default is 1 (EqualTo).

  • --use-enum-values
    Use strings from database instead of integer values.

  • --write-fully-qualified-names
    Write fully qualified names.

  • --write-counter
    Write counter.

  • --write-units-on-own-row
    Write units on an own row.

  • --write-data-frames
    Write both signals and data frames.

Examples

ck add signallogger dbcfile.engine.speed dbcfile.engine.gear --path path/to/logfile.csv --format csvsignal
ck add signallogger dbcfile.engine.speed dbcfile.engine.gear --path path/to/logfile.csv --format csvsignal --start-timeout 500 --stop-timeout 13000
ck add signallogger dbcfile.engine.speed dbcfile.engine.gear --path path/to/logfile.csv --format csvsignal --start-id 0x3F --stop-id 0x0F