CAN Send
The CAN Send pane allows you to manually send individual CAN or CAN FD messages on a selected CAN channel during an active measurement. It provides full control over message identifiers, flags, and data bytes, with optional signal-based editing when databases are loaded.
Overview
The CAN Send pane is useful for:
Testing ECU responses to specific messages
Injecting test data into a CAN network
Simulating missing network nodes
Manually triggering specific behaviors
Validating message handling in other nodes
Note
The CAN channel must be online (measurement running) to send messages.
Configuration Sections
Channel Selection
Select the CAN channel on which to transmit messages. The dropdown displays all CAN Channel source nodes configured in the Measurement Setup view.
Note
Only channels that are online and in a transmit-capable access mode can send messages.
CAN Identifier
Configure the message identifier and format:
- Identifier Value
Enter the CAN identifier in hexadecimal (without 0x prefix) or decimal format.
Standard (11-bit): 0x000 to 0x7FF (0 to 2047)
Extended (29-bit): 0x00000000 to 0x1FFFFFFF (0 to 536870911)
- Identifier Format
Select the CAN identifier type:
STD - Standard 11-bit identifier
EXT - Extended 29-bit identifier
CAN FD Options (when available):
FD - CAN FD format flag
BRS - Bit Rate Switch flag (allows higher data phase bit rate in CAN FD)
Remote Frame
RTR - Remote Transmission Request flag (standard CAN only)
Message Data
Configure the message data payload:
- Data Length
For CAN: 0 to 8 bytes
For CAN FD: 0 to 64 bytes
Data Entry Methods:
Byte-by-byte entry - Enter each data byte in hexadecimal (00-FF)
Signal-based entry (when database loaded) - Enter engineering values for each signal
- Byte Layout
Data bytes are displayed in order (Byte 0, Byte 1, Byte 2, etc.) with hexadecimal input fields.
Database Message Support
When a Databases data processor is added to the CAN channel in the Measurement Setup view, the CAN Send pane can work with database-defined messages and signals.
Selecting a Database Message
Click the Select Message button
Browse or search for a message in the loaded databases
Select the desired message
- When a message is selected:
The identifier is automatically set to the message’s ID
The identifier format (STD/EXT) is set correctly
The data length is set to the message’s defined length
Signal value editors appear
Signal Value Editing
When a database message is selected, you can edit signal values using:
Engineering values - Enter values in the signal’s defined unit (e.g., km/h, °C, rpm)
Automatic encoding - Signal values are automatically encoded into the message data bytes
Range validation - Values are validated against signal min/max ranges
The raw data bytes are automatically updated as you change signal values.
- Benefits of Signal-based Editing:
More intuitive than raw byte manipulation
Automatic handling of bit packing and byte order
Validation of value ranges
Display of units
Sending Messages
Send Feedback
There is no explicit confirmation when a message is sent. To verify transmission:
Use a Message Trace pane filtered to show Tx messages
Monitor the CAN Bus Statistics pane for Tx message count increases
Use external monitoring equipment
Typical Workflows
Manual Byte Entry
Select the target CAN channel
Enter the CAN identifier
Set the identifier format (STD or EXT)
Enter the data length
Enter data bytes in hexadecimal
Click Send
Database Message Entry
Ensure a Databases data processor is configured for the channel
Select the target CAN channel
Click Select Message and choose a database message
The identifier and format are set automatically
Enter signal values in their engineering units
Click Send
Testing ECU Responses
Configure a message that triggers an ECU behavior
Open a Message Trace pane to monitor responses
Click Send in the CAN Send pane
Observe the ECU’s response in the Message Trace
Tips and Best Practices
Identifier Entry
The identifier format (STD/EXT) affects the valid range of identifier values
Standard identifiers are more common in automotive applications
Extended identifiers are often used in industrial applications
Remember to set the correct format before entering the identifier
Data Entry
Use uppercase or lowercase for hexadecimal values (both work)
Leading zeros can be omitted (F is the same as 0F)
For multi-byte values, remember to consider byte order (endianness) based on your database
When using database signals, the byte order is handled automatically
CAN FD Usage
FD flag must be set for messages longer than 8 bytes
BRS flag enables higher data phase bit rates (if supported by hardware and bus configuration)
Ensure all nodes on the bus support CAN FD when using FD messages
Check that the CAN channel is configured for CAN FD mode in Measurement Setup
Troubleshooting
- Send button is disabled:
Check that a measurement is running
Verify the channel is online
Ensure the channel access mode allows transmission
Confirm the identifier and data length are valid
- Message doesn’t appear on bus:
Check that the channel is “On Bus” in CAN Bus Statistics
Verify bus termination and wiring
Check for bus-off condition
Ensure bit rate configuration matches the bus
- Database signals not available:
Add a Databases data processor to the channel in Measurement Setup
Load a database file (.dbc) containing the desired messages
Restart the measurement after adding the database
Check that the database contains the message ID you’re using
Integration with Other Panes
Message Trace - Monitor sent messages to verify transmission
CAN Bus Statistics - Check Tx message counts, error counters, and bus status
CAN Periodic Send - For repeated transmission instead of manual single sends
Signal Plot - Monitor signal responses after sending test messages
Comparing CAN Send vs CAN Periodic Send
- Use CAN Send when:
You need manual control over when messages are sent
Testing specific scenarios that require precise timing control
Sending one-time or infrequent messages
Triggering specific events
- Use CAN Periodic Send when:
You need continuous message transmission
Simulating a real ECU that sends periodic messages
Testing bus load scenarios
Maintaining node presence on the network