Kvaser CanKing GUI Extensions SDK v7.6.1
Kvaser CanKing GUI Extensions SDK / models / LogReplaySettings
Interface: LogReplaySettings
A message for defining a log replay’s settings.
Properties
channelIdentifiers
channelIdentifiers:
object
A dictionary consisting of the channels found in the log file mapped to the channel identifiers to be used when replaying the file.
Index Signature
[key: string]: string
higherVariance?
optionalhigherVariance?:number
Maximum waiting time variance (0-1) for how long to wait before sending the next message. The resulting range will be between the time factor and the time factor plus the higher variance.
includeErrorFrames
includeErrorFrames:
boolean
Replay error frames as well. Default value is false.
increaseSpeed?
optionalincreaseSpeed?:boolean
Increase the speed by the time factor. Default value is true.
iterations
iterations:
number
Number of iterations to loop the log file. Set to -1 to iterate forever. Default value is 1.
logFile
logFile:
string
Full path to the log file to read CAN frames from.
lowerVariance?
optionallowerVariance?:number
Minimum waiting time variance (0-1) for how long to wait before sending the next message. The resulting range will be between the time factor and the time factor minus the lower variance.
sampleRateMs
sampleRateMs:
number
Static sample rate in milliseconds to send the CAN frames at. If zero, timestamps from the log file will be used. Default value is 0.
sendFirstMessageMode
sendFirstMessageMode:
number
Send the first message straight away (1), after the time specified in the log file (2) or after an offset (3). Default value is 1 (send directly).
timeFactor?
optionaltimeFactor?:number
Factor in percentage for speeding up or down the waiting time until sending the next message.
timeOffsetMs?
optionaltimeOffsetMs?:number
Time offset in milliseconds until sending the first message. Default value is 0. This parameter shall be used together with the mode for sending the first message after an offset (3).
transceiverMode
transceiverMode:
number