.. _data_processor_nodes:

Data Processor Nodes
====================

Data processor nodes modify, filter, or enhance data flowing from source nodes before it reaches target nodes or the UI.

.. _can_message_filter_node:

CAN Message Filter
------------------

The CAN Message Filter processes CAN messages based on their identifiers, either passing or blocking specified IDs.

Configuration Options
~~~~~~~~~~~~~~~~~~~~~

* **Filter Mode** - Pass filter or Block filter
* **Standard CAN Identifiers** - List of 11-bit identifiers to filter (0x000-0x7FF)
* **Extended CAN Identifiers** - List of 29-bit identifiers to filter (0x00000000-0x1FFFFFFF)

Filter Modes
~~~~~~~~~~~~

* **Pass Filter** - Only allow specified identifiers through; block all others
* **Block Filter** - Block specified identifiers; allow all others through

Identifier Specification Format
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~

* Individual IDs: ``1,2,3``
* Ranges: ``100-200`` (includes all IDs from 100 to 200)
* Combined: ``1,5,10-20,100`` (IDs 1, 5, 10 through 20, and 100)

Use Cases
~~~~~~~~~

* Reducing bus traffic to the UI for better performance
* Isolating specific messages for focused analysis
* Excluding noisy or high-frequency messages from logging
* Pre-filtering data for specific test scenarios

Tips
~~~~

* Use pass filters when monitoring a small set of known messages
* Use block filters when you want to exclude a few known noisy messages
* Filters affect what reaches the UI and targets, but not the physical bus
* Consider filter performance with very large identifier ranges
* Multiple filters can be applied in series for complex filtering logic

.. _databases_node:

Databases
---------

The Databases data processor adds CAN or LIN database files to enable signal decoding and message naming throughout the application.

Configuration Options
~~~~~~~~~~~~~~~~~~~~~

* **Database Files** - List of .dbc (CAN) or .ldf (LIN) files to load
* **Multiple Files** - Can load multiple databases simultaneously

Database Types
~~~~~~~~~~~~~~

* **CAN Databases (.dbc)** - DBC files containing CAN message and signal definitions
* **LIN Databases (.ldf)** - LDF files containing LIN frame and signal definitions

What Databases Enable
~~~~~~~~~~~~~~~~~~~~~~

* Message names in Message Trace and other panes
* Signal names and values in expandable message rows
* Signal-based editing in send panes (CAN Send, LIN Send, etc.)
* Signal visualization in Signal Plot pane
* Signal logging in Signal Logger target node
* Unit and range information for signals

Use Cases
~~~~~~~~~

* Decoding messages in Message Trace with human-readable names
* Enabling signal-level logging instead of raw message logging
* Providing signal definitions for graphical visualization
* Simplifying message configuration with signal-based editing

Tips
~~~~

* Load databases early in your measurement setup configuration
* Multiple databases can be loaded for networks with multiple ECUs
* Database content is cached for performance with large files
* Signal decoding occurs in real-time during measurements
* Databases are required for meaningful signal logging and visualization

.. _j1939_interpreter_node:

J1939 Interpreter
-----------------

The J1939 Interpreter data processor decodes the CAN ID according to the J1939 protocol to PGN, priority, source address, and destination address.

.. note::
   The J1939 Interpreter is deprecated. For decoding J1939 messages, use the J1939 Annotator extension node instead.

.. _j1939_annotator_node:

J1939 Annotator
---------------

The J1939 Annotator is a CanKing service extension that decodes and annotates J1939 Transport Protocol (TP) traffic.

This extension listens to incoming J1939 frames (29-bit CAN IDs) and enriches them with base J1939 identifier metadata. For TP Connection Management (TP.CM, PGN ``0xEC00``) and Data Transfer (TP.DT, PGN ``0xEB00``) frames it also adds TP-specific decode and reassembly state.

It can also be configured to actively participate in CMDT (connection mode) transfers by transmitting CTS and EndAck control frames.

What It Does
~~~~~~~~~~~~

* Subscribes to received CAN frames with 29-bit IDs (J1939 format).
* Tracks TP sessions for both BAM (Broadcast Announce Message) and CMDT (RTS/CTS connection mode).
* Reassembles TP payload data from TP.DT packets.
* Annotates all J1939 frames with base properties (priority, PGN, source address, destination address).
* Adds TP-specific properties on TP.CM / TP.DT frames (control type, transported PGN, progress, payload on completion).
* Logs lifecycle events such as measurement start/stop, parse warnings, completed reassemblies, and session expiry.
* Optionally participates as an active CMDT receiver by sending CTS windows and EndAck.

Passive Observer Scope
~~~~~~~~~~~~~~~~~~~~~~

This extension is Rx-only and passive by design.

* It observes existing traffic and annotates frames in CanKing.
* Out-of-order BAM packets cause session drop.
* Out-of-order CMDT packets are tolerated by keeping session state and waiting for expected sequence.

When ``active_listening`` is enabled, the extension sends TP.CM CTS and EndAck frames for CMDT transfers.

.. note::
   This extension never sends segmented messages of its own. It can only receive segmented messages, not transmit.

Frame Properties Added
~~~~~~~~~~~~~~~~~~~~~~

Depending on frame type and decode state, the extension sets these frame properties:

.. list-table::
   :header-rows: 1
   :widths: 30 30 40

   * - Property
     - Set on
     - Value
   * - ``J1939.PGN``
     - All J1939 frames
     - Numeric PGN
   * - ``J1939.Source``
     - All J1939 frames
     - Source address (0-253)
   * - ``J1939.Destination``
     - All J1939 frames
     - Destination address (0-255)
   * - ``J1939.Priority``
     - All J1939 frames
     - Priority (0-7)
   * - ``J1939.TpControlType``
     - TP.CM frames (PGN ``0xEC00``)
     - ``"BAM"``, ``"RTS"``, ``"CTS"``, ``"EndAck"``, ``"Abort"``, or ``"Unknown"``
   * - ``J1939.TpPGN``
     - All TP.CM and TP.DT frames
     - Transported-message PGN
   * - ``J1939.TpTotalBytes``
     - TP.CM BAM, RTS, EndAck frames
     - Total payload bytes declared in the frame
   * - ``J1939.TpNumPackets``
     - TP.CM BAM, RTS, EndAck frames
     - Total TP.DT packet count declared in the frame
   * - ``J1939.TpMaxPacketsPerCts``
     - TP.CM RTS frames
     - Maximum packets per CTS window the sender will accept
   * - ``J1939.TpCtsNumPackets``
     - TP.CM CTS frames
     - Number of DT packets the sender may transmit in this window
   * - ``J1939.TpCtsNextPacket``
     - TP.CM CTS frames
     - Sequence number of the first DT packet expected in this window
   * - ``J1939.TpAbortReason``
     - TP.CM Abort frames
     - Abort reason code
   * - ``J1939.TpSeqNo``
     - TP.DT frames (PGN ``0xEB00``)
     - Sequence number byte (1-255)
   * - ``J1939.TpSessionProgress``
     - TP.DT frames with an active session
     - ``"received/total"`` byte count
   * - ``J1939.TpReassemblyComplete``
     - Last TP.DT of a complete message
     - ``"true"``
   * - ``J1939.TpPayloadHex``
     - Last TP.DT of a complete message
     - Uppercase hex of reassembled payload
   * - ``J1939.TpActiveAction``
     - TP.CM RTS (active mode); TP.DT at window boundary or final packet
     - ``"CTS sent"`` or ``"EndAck sent"``

Configuration
~~~~~~~~~~~~~

Configuration is JSON and can be changed at runtime via the CanKing extension config.

Default configuration:

.. code-block:: json

   {
     "session_timeout_ms": 750,
     "filter_pgns": [],
     "filter_source_addresses": [],
     "active_listening": false,
     "active_receiver_addresses": [],
     "active_cts_window_size": 255
   }

Configuration fields:

* **session_timeout_ms** - T1-style inactivity timeout in milliseconds used for new sessions.
* **filter_pgns** - Allow-list of transported PGNs to annotate. An empty list means all PGNs are annotated.
* **filter_source_addresses** - Allow-list of source addresses to annotate. An empty list means all source addresses are annotated.
* **active_listening** - Enable active CMDT participation (sends CTS and EndAck). Default ``false``.
* **active_receiver_addresses** - Local destination addresses this extension may act as receiver for in CMDT. Active mode only sends CTS/EndAck when the RTS destination matches one of these addresses.
* **active_cts_window_size** - Maximum packets requested per CTS. The effective value is clamped against the sender RTS byte 4 and remaining packets.

.. _isotp_annotator_node:

ISO-TP Annotator
----------------

The ISO-TP Annotator is a CanKing service extension that decodes and annotates ISO-TP (ISO 15765-2) traffic on CAN and CAN-FD buses.

The extension observes incoming frames, recognizes the four ISO-TP frame types (Single Frame, First Frame, Consecutive Frame, Flow Control), reassembles multi-frame messages from their constituent Consecutive Frames, and enriches every matching frame with protocol metadata as CanKing frame properties.

It can also be configured to actively participate in transfers by enabling ``active_listening``, which makes the extension send Flow Control (FC) frames — both the initial CTS after a First Frame and subsequent CTS frames at block boundaries when ``fc_block_size > 0``.

What It Does
~~~~~~~~~~~~

* Subscribes to CAN and CAN-FD frames and applies configurable direction and ID-type filters.
* Recognizes all four ISO-TP PCI types: SF (Single Frame), FF (First Frame), CF (Consecutive Frame), FC (Flow Control).
* Reassembles multi-frame payloads from FF + CF sequences, with strict SN validation (wrong SN drops the session).
* Annotates every recognized frame with ISO-TP metadata as named frame properties visible in CanKing.
* Supports classic CAN (DLC ≤ 8) and CAN-FD long-length encoding (DLC > 8 SF/FF) per ISO 15765-2.
* Supports ISO-TP extended addressing (N_TA byte before PCI byte).
* Logs lifecycle events: session start/stop, session expiry, and completed reassemblies.
* Optionally participates as an active receiver when ``active_listening`` is enabled: sends FC(CTS) after a First Frame and at every block boundary when ``fc_block_size > 0``.

Passive Observer Scope
~~~~~~~~~~~~~~~~~~~~~~

Set ``active_listening`` to ``false`` to turn the extension into a pure passive observer.

* It does not transmit any frames when ``active_listening`` is ``false``, or when ``active_addresses`` is empty.
* It observes existing ISO-TP traffic and annotates frames in CanKing.
* A wrong Consecutive Frame SN causes the session to be dropped.
* Sessions that receive no Consecutive Frame within ``session_timeout_ms`` are expired and logged.

``active_addresses`` controls which frames are annotated regardless of ``active_listening``. When ``active_listening`` is enabled, the extension additionally sends FC(ContinueToSend) frames for those addresses so the sender proceeds with data transfer.

.. note::
   This extension never sends segmented messages of its own. It can only receive segmented messages, not transmit.

Frame Properties Added
~~~~~~~~~~~~~~~~~~~~~~

Depending on frame type and decode state, the extension sets these frame properties:

.. list-table::
   :header-rows: 1
   :widths: 30 30 40

   * - Property
     - Set on
     - Value
   * - ``ISOTP.FrameType``
     - All recognised frames
     - ``"SF"``, ``"FF"``, ``"CF"``, or ``"FC"``
   * - ``ISOTP.TpTotalBytes``
     - SF; FF
     - Payload/Total message length in bytes
   * - ``ISOTP.TpFirstDataHex``
     - FF
     - Hex of data bytes carried in the FF itself
   * - ``ISOTP.TpSeqNo``
     - CF
     - Sequence number nibble (0-15)
   * - ``ISOTP.TpSessionProgress``
     - CF
     - ``"received/total"`` byte count
   * - ``ISOTP.TpFlowStatus``
     - FC
     - ``"CTS"``, ``"Wait"``, ``"Overflow"``, or ``"Reserved"``
   * - ``ISOTP.TpBlockSize``
     - FC
     - Block size byte value
   * - ``ISOTP.TpSeparationTimeUs``
     - FC
     - STmin decoded to microseconds
   * - ``ISOTP.TpReassemblyComplete``
     - Last CF of a complete message
     - ``"true"``
   * - ``ISOTP.TpPayloadHex``
     - SF; last CF of a complete message
     - Uppercase hex string of payload / reassembled data
   * - ``ISOTP.TpActiveAction``
     - FF (on active FC send); CF at block boundary
     - ``"FC sent"``

Configuration
~~~~~~~~~~~~~

Configuration is JSON and can be changed at runtime via the CanKing extension config panel.

Default configuration:

.. code-block:: json

   {
     "session_timeout_ms": 1000,
     "extended_addressing": false,
     "extended_id": false,
     "active_listening": true,
     "active_addresses": [
       {
         "rx_can_id": 2024,
         "tx_can_id": 2016,
         "rx_address_extension": null,
         "tx_address_extension": null
       }
     ],
     "broadcast_id": 2015,
     "fc_block_size": 0,
     "fc_stmin": 0,
     "fc_padding": 204,
     "fc_use_brs": false
   }

The default ``active_addresses``, ``fc_padding``, and ``broadcast_id`` values correspond to the standard OBD-II engine ECU scenario:

.. list-table::
   :header-rows: 1
   :widths: 15 15 70

   * - Hex
     - Decimal
     - Role
   * - ``0x7E8``
     - 2024
     - Engine ECU response address (``rx_can_id``)
   * - ``0x7E0``
     - 2016
     - Tester physical request address (``tx_can_id``)
   * - ``0x7DF``
     - 2015
     - OBD-II functional broadcast address (``broadcast_id``)
   * - ``0xCC``
     - 204
     - ISO 15765-2 recommended padding byte (``fc_padding``)

Configuration fields:

* **session_timeout_ms** - Inactivity timeout for multi-frame sessions. A session is discarded if no Consecutive Frame arrives within this window.
* **extended_addressing** - When ``true``, the first byte of each CAN data field is the N_TA address extension and the PCI byte is at offset 1. Default ``false``.
* **extended_id** - Restrict to extended (29-bit) CAN IDs when ``true``; standard (11-bit) IDs when ``false``. Default ``false``.
* **active_listening** - When ``true``, the extension actively participates as a receiver and sends FC frames for the sessions matching ``active_addresses``. When ``false``, the extension never transmits; ``active_addresses`` still controls which frames are annotated. Default ``true``.
* **active_addresses** - Each entry has the following fields:

  * **rx_can_id** - CAN ID on which the remote node sends First Frames to us.
  * **tx_can_id** - CAN ID used when sending FC frames back.
  * **rx_address_extension** *(optional)* - Expected N_TA byte (``data[0]``) in received frames when ``extended_addressing`` is ``true``. When ``null``, any extension byte is accepted. Ignored when ``extended_addressing`` is ``false``.
  * **tx_address_extension** *(optional)* - N_TA byte prepended to outgoing FC frames when ``extended_addressing`` is ``true``. When ``null``, no extension byte is added. Ignored when ``extended_addressing`` is ``false``.

  Frames matching an entry are always annotated. With ``active_listening`` enabled, a First Frame arriving on ``rx_can_id`` (with matching ``rx_address_extension`` if applicable) also causes an FC(CTS) to be sent on ``tx_can_id`` with ``tx_address_extension`` prepended. Empty list = fully passive. Default: OBD-II engine ECU pair (0x7E8 / 0x7E0).

* **broadcast_id** - Passive-mode CAN ID filter. When set, non-active frames are only annotated if their CAN ID equals this value. Set to ``null`` to annotate all non-active frames. Default ``2015`` (0x7DF).
* **fc_block_size** - Block size (BS) byte sent in all outgoing FC frames. ``0`` means unlimited — the sender may transmit all remaining frames without further FC. Default ``0``.
* **fc_stmin** - Separation time minimum byte sent in all outgoing FC frames, ISO 15765-2 encoded. ``0x00``-``0x7F`` = 0-127 ms; ``0xF1``-``0xF9`` = 100-900 µs; other values = 127 ms fallback. Default ``0``.
* **fc_padding** - Padding byte used to fill outgoing FC frames to 8 bytes. Set to ``null`` to send only the mandatory 3 bytes (PCI + BS + STmin) with no padding. Default ``204`` (0xCC).
* **fc_use_brs** - Enable Bit Rate Switch (BRS) in outgoing FC frames when CAN-FD is used. Has no effect on classic CAN frames.

Active Receiver Flow
~~~~~~~~~~~~~~~~~~~~

With ``active_listening`` enabled and ``fc_block_size = 0`` (unlimited):

.. code-block:: text

   ECU → FF (on rx_can_id)    → extension sends FC(BS=0) on tx_can_id
   ECU → CF sn=1
   ECU → CF sn=2
   …
   ECU → CF last              → message reassembled, ISOTP.TpPayloadHex annotated

When ``fc_block_size = 2``:

.. code-block:: text

   ECU → FF (on rx_can_id)    → extension sends FC(BS=2)
   ECU → CF sn=1
   ECU → CF sn=2              → extension sends FC(BS=2)   ← block boundary
   ECU → CF sn=3
   ECU → CF sn=4              → extension sends FC(BS=2)   ← block boundary
   …
   ECU → CF last              → message reassembled