Measurement Setup view

The Measurement Setup view shows the current configuration, i.e. which Kvaser interfaces that are currently configured to be used and how to handle the data they receive. The configuration is illustrated as a node graph that is orientated from left to right, where a node corresponds to a specific Kvaser interface or a feature such as logging messages. The Measurement Setup view opens automatically after creating a new or selecting a saved project, but can also be opened from the vertical tool bar to the left of the application.

An example of a measurement setup is provided below. It contains two Kvaser virtual CAN channels, a Traffic Generator node for generating data on CAN 2 and a pass-through filter on CAN 1. The data is transmitted to a stream.

An example of a measurement setup using Kvaser virtual CAN channels.

A measurement can optionally be kept running in the background even if the Kvaser CanKing application is closed. This can be configured in the user settings.

Nodes

A node has one of three types:

  • Source

  • Data processor

  • Target

All Kvaser interfaces are source nodes, but there is also a source node for replaying log files and generating CAN traffic. A data processor parses the data transmitted from a source node and may for example consist of a database (.dbc file) or a filter. A target node, on the other hand, could be a Message Logger or Signal Logger. All data is also transmitted to a stream (denoted as ‘UI Streams’ in the Measurement Setup view). For a list of all available nodes, sorted according to type, see Standard Nodes.

A node may be enabled or disabled in a measurement setup.

Standard Nodes

This section describes all available standard nodes in detail, including their configuration options, use cases, and best practices.

Customized Nodes

A user may create customized nodes to be able to get additional functionality, like for example a gateway or a cloud connector. Such extension is developed as a Web Assembly component which will be hosted by the Kvaser CanKing service. Once installed, the extension will be available as a node in the Measurement Setup view and able to interact with the CAN and LIN bus.

For more information about service extensions, including examples and how to install them, see the separate guide found in the tool bar in the Kvaser CanKing application by selecting Help followed by CanKing Service Extensions SDK Help….

Node Management

This section describes how to add, configure, and manage nodes in the Measurement Setup view.

Adding Nodes

Adding Source Nodes:

  1. In the Measurement Setup view, click the Source button

  2. Select the desired source node type from the menu

  3. Configure the node settings in the dialog

  4. Click Create to add the node

Adding Data Processor Nodes:

  1. Click the + button on an existing source node

  2. Select the desired data processor type

  3. Configure the processor settings

  4. Click Create to insert the processor

Data processors are inserted between the source node and the UI stream, processing all data flowing through that path.

Adding Target Nodes:

  1. Click the Target button

  2. Select the desired target node type

  3. Configure the target settings (file paths, formats, etc.)

  4. Click Create to add the target

Target nodes receive data from all sources after processing.

Configuring Nodes

To edit an existing node:

  1. Click the Edit button (pen icon) on the node

  2. Modify the settings as needed

  3. Click Save to apply changes

Note

Nodes cannot be edited while a measurement is running. Stop the measurement first.

Enabling and Disabling Nodes

Nodes can be temporarily disabled without removing them:

  1. Click the Enable/Disable button on the node

  2. Disabled nodes appear grayed out

  3. Click again to re-enable

Disabled nodes:
  • Do not participate in measurements

  • Retain their configuration

  • Can be quickly re-enabled when needed

Use Cases:

  • Temporarily exclude a channel without removing configuration

  • Test different measurement configurations quickly

  • Disable expensive data processing during initial testing

Deleting Nodes

To remove a node:

  1. Click the Delete button (trash icon) on the node

  2. Confirm the deletion when prompted

Warning

Deleting a node removes its configuration permanently. Consider disabling instead if you may need it later.

Node Controls (Source Nodes)

Some source nodes have additional runtime controls:

Bus On/Off (CAN Channel):
  • Toggle whether the CAN controller is active on the bus

  • Useful for temporarily disconnecting from the bus without stopping the measurement

  • Green indicator shows “on bus” state

Start/Stop (Traffic Generator, Log Replay):
  • Control traffic generation independently of the measurement

  • Allows starting/stopping data generation while monitoring continues

Best Practices

Measurement Setup Design

Keep It Simple:
  • Start with minimal configuration and add complexity as needed

  • Use descriptive names for channels when multiple interfaces are connected

  • Disable unused nodes rather than creating separate projects

Logical Data Flow:
  • Organize nodes left-to-right following the data flow

  • Use consistent configurations across similar channels

Performance Considerations:
  • Apply filters early (close to source) to reduce downstream processing

  • Load only necessary databases to minimize decoding overhead

  • Use binary log formats (KME, MDF) for better performance than text formats

Channel Configuration

CAN Channel Best Practices:
  • Verify bit rate matches your network before connecting

  • Consider silent mode for error injection testing

  • Lock to serial number for reproducible hardware configurations

LIN Channel Best Practices:
  • Ensure only one master is active on the network

  • Load databases with schedule tables for master channels

  • Configure slave responses before starting measurements

  • Enable “Save LIN message info” for detailed protocol analysis

Database Management

  • Load databases early in your setup (before other processors)

  • Use descriptive database file names for easy identification

  • Keep database files with your project for portability

  • Update databases when ECU software changes

  • Verify database versions match your hardware/software configuration

Filtering Strategy

  • Use pass filters for focused analysis on known messages

  • Use block filters to remove known noise sources

  • Combine multiple filters for complex scenarios

  • Remember: filters affect data to UI and targets, not the physical bus

  • Test filter configurations before long measurements

Logging Strategy

File Format Selection:
  • Use KME for best performance and replay capability

  • Use MDF for compatibility with industry tools

  • Use CSV for human-readable output and custom processing

  • Use Vector formats when integrating with CANoe/CANalyzer

File Management:
  • Enable “Append index” to prevent accidental overwrites

  • Use descriptive file names with date/time or test identifiers

  • Store log files in a consistent directory structure

  • Consider disk space for long-running measurements

  • Archive important logs regularly

What to Log:
  • Log messages when you need raw data or timestamps

  • Log signals when you need processed, engineering values

  • Consider logging both for comprehensive analysis

  • Select specific signals in Signal Logger to reduce file size

Testing and Validation

Before Starting Measurements:
  • Verify all hardware connections

  • Check bit rate configurations match bus speeds

  • Test with short measurements before long captures

  • Verify log file paths are valid and have sufficient disk space

  • Confirm databases are loaded correctly

During Measurements:
  • Monitor bus load indicators at the bottom of the window

  • Watch for errors in the Log view (Tools Panel)

  • Check that logger status shows “Started”

  • Verify UI stream is receiving expected data

After Measurements:
  • Confirm log files were created and contain data

  • Check file sizes are reasonable

  • Verify timestamps and data integrity

  • Archive important measurements with project files

Troubleshooting

Common Issues:

  • Interface not appearing - Check hardware connections, drivers

  • Bus errors - Verify bit rate, termination, cable quality

  • No data received - Check filters, disabled nodes, bus connectivity

  • Logger not writing - Verify file path, disk space, permissions

  • Performance issues - Reduce filters, limit databases, lower bus traffic

Diagnostic Steps:

  1. Check Tools Panel > Log for error messages

  2. Verify measurement status indicator (green = running)

  3. Review node states (enabled/disabled, on bus/off bus)

  4. Test with simplified configuration (minimal nodes)

  5. Consult documentation for specific error codes