ck add messagelogger

Adds a Message Logger to the current measurement setup.

Only one type of trigger can be used at a time for start and stop seperatly. The available triggers are Timeout, Signal and Identifier.

The supported file formats are: csv, mdf, mdfv4, txt, asc, blf, blffd, kme, kme25, kme40, kme50

The signal operators that can be used are: 1 (EqualTo), 2 (NotEqualTo), 3 (LessThan), 4 (LessThanOrEqual), 5 (GreaterThanOrEqual), 6 (GreaterThan)

Synopsis

messagelogger [--auto-restart] [--col-separator] [--data-bytes-converter-limit] [--decimal-separator] [--ext-ids] [--filter-type] [-f|--format] [-l|--language] [-n|--name] [-p|--path] [--size-limit] [--skip-file-header] [--start-id] [--start-operator] [--start-signal-qualified-name] [--start-signal-value] [--start-timeout] [--std-ids] [--stop-id] [--stop-operator] [--stop-signal-qualified-name] [--stop-signal-value] [--stop-timeout] [--time-decimals] [--time-limit] [--time-reference] [--use-calendar-time] [--use-local-time] [--write-data-in-dec] [--write-id-in-dec]

Description

Adds a Message Logger to the current measurement setup.

Only one type of trigger can be used at a time for start and stop seperatly. The available triggers are Timeout, Signal and Identifier.

The supported file formats are: csv, mdf, mdfv4, txt, asc, blf, blffd, kme, kme25, kme40, kme50

The signal operators that can be used are: 1 (EqualTo), 2 (NotEqualTo), 3 (LessThan), 4 (LessThanOrEqual), 5 (GreaterThanOrEqual), 6 (GreaterThan)

Options

  • --auto-restart

    Automatically restart after stop.

  • --col-separator

    Use either a comma (1) or semicolon (2) as the column separator. Default value is a comma (1).

  • --data-bytes-converter-limit

    Number of data bytes a converter will max write to the log file (1-64). Default value is 64.

  • --decimal-separator

    Use either a dot (1) or comma (2) as the decimal separator. Default value is a dot (1).

  • --ext-ids

    The extended CAN IDs to be filtered. Example: “1,2,3,5-10” in order to filter IDs 1,2,3 and 5 to 10. Prefix IDs with 0x to indicate hex format.

  • --filter-type

    The filter type. Either block or pass CAN IDs through filter. Default: pass

  • -f|--format

    Format of the file to log messages to. If not given the format will be extracted from the path.

  • -l|--language

    Specify the preferred language to be used in all output strings. Default value is English (en).

  • -n|--name

    Name of the node. Default value is ‘Message Logger’

  • -p|--path

    Name of the file to log messages to, including full path (required).

  • --size-limit

    Max file size in megabytes before writing to a new file.

  • --skip-file-header

    Skip writing file header

  • --start-id

    The Message ID to use as start trigger. Prefix with 0x to indicate hex format.

  • --start-operator

    The operator to use as start trigger. Default is 1 (EqualTo).

  • --start-signal-qualified-name

    The Signal Qualified Name to use as start.

  • --start-signal-value

    The Signal Value to use as start trigger. Prefix with 0x to indicate hex format.

  • --start-timeout

    A timeout in milliseconds, to be used as start trigger.

  • --std-ids

    The standard CAN IDs to be filtered. Example: “1,2,3,5-10” in order to filter IDs 1,2,3 and 5 to 10. Prefix IDs with 0x to indicate hex format.

  • --stop-id

    The Message ID to use as stop trigger. Prefix with 0x to indicate hex format.

  • --stop-operator

    The operator to use as stop trigger. Default is 1 (EqualTo).

  • --stop-signal-qualified-name

    The Signal Qualified Name to use as stop.

  • --stop-signal-value

    The Signal Value to use as stop trigger. Prefix with 0x to indicate hex format.

  • --stop-timeout

    A timeout in milliseconds, to be used as stop trigger.

  • --time-decimals

    Number of time decimals (0-9). Default value is

  • --time-limit

    Max number of seconds between first and last event before writing to a new file.

  • --time-reference

    Use either first trigger (1) or start of measurement (2) as time reference. Default value is 1 (first trigger).

  • --use-calendar-time

    Write timestamps in calendar time instead of seconds.

  • --use-local-time

    Use local time instead of UTC for absolute timestamps.

  • --write-data-in-dec

    Write data in decimal format.

  • --write-id-in-dec

    Write ID in decimal format.

Examples

  • ck add messagelogger --name "Message Logger" -p path/to/logfile --format csv

  • ck add messagelogger --name "Message Logger" -p path/to/logfile --format csv --start-timeout 500 --stop-timeout 13000

  • ck add messagelogger --name "Message Logger" -p path/to/logfile --format csv --start-id 0x3F --stop-id 0x0F

  • ck add messagelogger --name "Message Logger" -p path/to/logfile --format csv --start-id 0x3F --stop-id 0x0F --start-signal-qualified-name dbcfile.startsignal --stop-signal-qualified-name dbcfile.stopsignal --start-signal-value 0xAB --stop-signal-value 0x12