# ck add signallogger

Adds a Signal Logger to the current measurement setup.

Only one type of trigger can be used at a time for start and stop seperatly. The
available triggers are Timeout, Signal and Identifier.

The supported file formats are: csv, mdf, mdfv4, mat, dat

The signal operators that can be used are: 1 (EqualTo), 2 (NotEqualTo), 3 
(LessThan), 4 (LessThanOrEqual), 5 (GreaterThanOrEqual), 6 
(GreaterThan)

## Synopsis

```signallogger [SIGNALS] [--auto-restart] [--col-separator] [--data-bytes-converter-limit] [--data-decimals] [--decimal-separator] [-f|--format] [-l|--language] [-n|--name] [-p|--path] [--size-limit] [--skip-file-header] [--start-id] [--start-operator] [--start-signal-qualified-name] [--start-signal-value] [--start-timeout] [--stop-id] [--stop-operator] [--stop-signal-qualified-name] [--stop-signal-value] [--stop-timeout] [--time-decimals] [--time-limit] [--time-reference] [--use-calendar-time] [--use-enum-values] [--use-local-time] [--write-counter] [--write-data-frames] [--write-data-in-dec] [--write-fully-qualified-names] [--write-id-in-dec] [--write-units-on-own-row]```

## Description

Adds a Signal Logger to the current measurement setup.

Only one type of trigger can be used at a time for start and stop seperatly. The
available triggers are Timeout, Signal and Identifier.

The supported file formats are: csv, mdf, mdfv4, mat, dat

The signal operators that can be used are: 1 (EqualTo), 2 (NotEqualTo), 3 
(LessThan), 4 (LessThanOrEqual), 5 (GreaterThanOrEqual), 6 
(GreaterThan)

## Arguments

- `SIGNALS`
	
	 A comma separated list containing the qualified names of 
the signals to log.

## Options

- `--auto-restart`
	
	 Automatically restart after stop.

- `--col-separator`
	
	 Use either a comma (1) or semicolon (2) as the column 
separator. Default value is a comma (1).

- `--data-bytes-converter-limit`
	
	 Number of data bytes a converter will max write to the 
log file (1-64). Default value is 64.

- `--data-decimals`
	
	 Number of data decimals (0-9). Default value is 
4.

- `--decimal-separator`
	
	 Use either a dot (1) or comma (2) as the decimal 
separator. Default value is a dot (1).

- `-f|--format`
	
	 Format of the file to log messages to. If not given the 
format will be extracted from the path.

- `-l|--language`
	
	 Specify the preferred language to be used in all output 
strings. Default value is English (en).

- `-n|--name`
	
	 Name of the node. Default value is 'Signal 
Logger'

- `-p|--path`
	
	 Name of the file to log messages to, including full path 
(required).

- `--size-limit`
	
	 Max file size in megabytes before writing to a new 
file.

- `--skip-file-header`
	
	 Skip writing file header

- `--start-id`
	
	 The Message ID to use as start trigger. Prefix with 0x to
indicate hex format.

- `--start-operator`
	
	 The operator to use as start trigger. Default is 1 
(EqualTo).

- `--start-signal-qualified-name`
	
	 The Signal Qualified Name to use as start.

- `--start-signal-value`
	
	 The Signal Value to use as start trigger. Prefix with 0x 
to indicate hex format.

- `--start-timeout`
	
	 A timeout in milliseconds, to be used as start 
trigger.

- `--stop-id`
	
	 The Message ID to use as stop trigger. Prefix with 0x to 
indicate hex format.

- `--stop-operator`
	
	 The operator to use as stop trigger. Default is 1 
(EqualTo).

- `--stop-signal-qualified-name`
	
	 The Signal Qualified Name to use as stop.

- `--stop-signal-value`
	
	 The Signal Value to use as stop trigger. Prefix with 0x 
to indicate hex format.

- `--stop-timeout`
	
	 A timeout in milliseconds, to be used as stop 
trigger.

- `--time-decimals`
	
	 Number of time decimals (0-9). Default value is 
9.

- `--time-limit`
	
	 Max number of seconds between first and last event before
writing to a new file.

- `--time-reference`
	
	 Use either first trigger (1) or start of measurement (2) 
as time reference. Default value is 1 (first trigger).

- `--use-calendar-time`
	
	 Write timestamps in calendar time instead of 
seconds.

- `--use-enum-values`
	
	  Use strings from database instead of integer 
values.

- `--use-local-time`
	
	 Use local time instead of UTC for absolute 
timestamps.

- `--write-counter`
	
	 Write counter.

- `--write-data-frames`
	
	 Write both signals and data frames.

- `--write-data-in-dec`
	
	 Write data in decimal format.

- `--write-fully-qualified-names`
	
	 Write fully qualified names.

- `--write-id-in-dec`
	
	 Write ID in decimal format.

- `--write-units-on-own-row`
	
	 Write units on an own row.

## Examples

- ```ck add signallogger dbcfile.engine.speed dbcfile.engine.gear --name "Signal Logger" -p path/to/logfile --format csvsignal```

- ```ck add signallogger dbcfile.engine.speed dbcfile.engine.gear --name "Signal Logger" -p path/to/logfile --format csvsignal --start-timeout 500 --stop-timeout 13000```

- ```ck add signallogger dbcfile.engine.speed dbcfile.engine.gear --name "Signal Logger" -p path/to/logfile --format csvsignal --start-id 0x3F --stop-id 0x0F```

- ```ck add signallogger dbcfile.engine.speed dbcfile.engine.gear --name "Signal Logger" -p path/to/logfile --format csvsignal --start-id 0x3F --stop-id 0x0F --start-signal-qualified-name dbcfile.startsignal --stop-signal-qualified-name dbcfile.stopsignal --start-signal-value 0xAB --stop-signal-value 0x12```