Field Description Theme A select box to select the user interface theme. Possible themes are 'Light Mode' and 'Dark Mode'. Languange A select box to select the language to be used in the user interface. Numeric Base A select box to select the default numeric base for message identifiers and message data. Possible values are 'Hexadecimal' and 'Decimal'. Closing Action A select box to select what action to perform when the application is closing. Possible values are 'Prompt for action', 'Stop measurement and clear setup' and 'Keep any measurement running'.
Field Description Name A name that will be used in CanKing to reference this node. Interface A select box to point out which hardware interface and channel to be used. S/N A read-only field displaying the serial number of the selected hardware interface. Locked to S/N A check box that locks the CAN Channel to the interface with the specified serial number instead of locking to the CANLib channel number. Selecting this option will guarantee that the CAN Channel always uses the same hardware interface. Rescan A button that triggers a rescan of the computer for added hardware interfaces. CAN Mode A select box to select CAN mode. Possible values are 'CAN', 'CAN FD' and 'CAN FD NONISO'. Access Mode A select box to select access mode to be used when initializing the interface. Possible values are 'Init Access', 'No Init Access' and 'Exclusive Access'. 'Init Access' will try to initialize the interface by setting the selected bus speed. If any other application is connected to the same interface with init access, then this will fail. 'No Init Access' will prevent CanKing from setting the interface's bus speed. 'Exclusive Access' will make sure that only CanKing is connected to the interface. Silent Mode A check box that makes the interface acting in silent mode. This setting is disabled if the interface doesn't support silent mode. Bus Speed A select box with a predefined list of bus speeds. SJW A select box with possible SJW values for the selected bus speed. Bit Timing A button that opens a table with all possible bit timing combinations for the selected bit rate. This table can be used to select bit timings that isn't listed in the 'Bus Speed' select box.
Field Description Name A name that will be used in CanKing to reference this node. Channel A select box to select which CAN Channel to send out CAN messages on. CAN Identifier A set of fields to control the CAN identifier(s) to be used in the CAN messages. Constant identifier: The same identifier is used by every message. Random identifier: Identifier to use is picked by taking a random identifier from a specified range. Scan identifier: Identifier to use is picked from a specified range. Frame Definition A set of field to control what kind of CAN frame to send out and what data it should contain. Frame type is selected from a select box. Possible frame types are 'CAN', 'CAN FD' and 'ERRORFRAME'. For a classic CAN frame it's possible to select if it should be a 'remote request frame'. For a CAN FD frame it's possible to select if 'bit rate switch' should be used. Both classic CAN and CAN FD frames can be sent out as single shot, no retransmission on collision. Frame data is defined by selecting message data length and by editing the message raw data by entering the value of each byte. Both the message data length and the message raw data can be randomized. Transmission Interval A set of fields to control the transmission interval. Constant interval: The same interval is used between each transmission. Random interval: Interval to use is picked by taking a random interval from a specified range. Scan interval: Interval to use is picked from a specified range. Number of Messages Specifies a fixed number of messages to be sent out or unlimited number of messages. Burst Size A set of fields to control the burst size, i.e. the number of messages to be sent out at every sample point. Constant burst size: The same number of messages are sent out at every sample point. Random burst size: Burst size to use is picked by taking a random value from a specified range.
Field Description Name A name that will be used in CanKing to reference this node. Filter Type A radio button group with one button for 'Pass Filter' and one button for 'Block Filter' Std CAN Identifiers A text field to list which standard (11-bit) CAN identifiers that should be filtered out. The identifiers can be listed individually as a comma separated list or in ranges, for example the string 1,2,3,6-10 will filter out identifiers 1, 2, 3 and 6 to 10. Ext CAN Identifiers A text field to list which extended (29-bit) CAN identifiers that should be filtered out. The identifiers can be listed individually as a comma separated list or in ranges, for example the string 1,2,3,6-10 will filter out identifiers 1, 2, 3 and 6 to 10. Sources A check box list with all measurement setup nodes that can be connected as sources to this node.
Field Description Name A name that will be used in CanKing to reference this node. DBC Files An 'Add' button to browse and add database files and a list of selected files. Sources A check box list with all measurement setup nodes that can be connected as sources to this node.
Field Description Name A name that will be used in CanKing to reference this node. File Format A select box to select what file format the log file should use. File Name A text field and a 'Browse...' button to enter full path to the log file to be created. File Name Action A radio button group to decide what should happen if a file already exists with for the specified file name. Possible options are: - Append next available index to the file name - Append timestamp to the file name - Overwrite any existing file Start Trigger A radio button group to decide what kind of trigger that should start the logger. Possible triggers are: - Start Measurement: The logger starts when a new measurement is started. - Timer: The logger starts at a specified time after the measurement was started. - Message: The logger starts when a message with a specified CAN identifier has been received. - Signal Value: The logger starts when a signal value expression has been fulfilled. Stop Trigger A radio button group to decide what kind of trigger that should stop the logger. Possible triggers are: - Stop Measurement: The logger stops when the measurement is stopped. - Timer: The logger stops at a specified time after the logger was started. - Message: The logger stops when a message with a specified CAN identifier has been received. - Signal Value: The logger stops when a signal value expression has been fulfilled. Sources A check box list with all measurement setup nodes that can be connected as sources to this node.
Field Description Channel A select box to select which CAN Channel to send out CAN messages on. CAN Identifier A set of fields to control the CAN identifier to be used in the CAN message. Frame Definition A set of field to control what kind of CAN frame to send out and what data it should contain. Frame type is selected from a select box. Possible frame types are 'CAN', 'CAN FD' and 'ERRORFRAME'. For a classic CAN frame it's possible to select if it should be a 'remote request frame'. For a CAN FD frame it's possible to select if 'bit rate switch' should be used. Both classic CAN and CAN FD frames can be sent out as single shot, no retransmission on collision. Frame data is defined by selecting message data length and by editing the message raw data by entering the value of each byte. The message raw data can be randomized by clicking on the 'Randomize Data' button.
Field Description Channel A select box to select which CAN Channel to send out CAN messages on. CAN Identifier A set of fields to control the CAN identifier(s) to be used in the CAN messages. Constant identifier: The same identifier is used by every message. Random identifier: Identifier to use is picked by taking a random identifier from a specified range. Scan identifier: Identifier to use is picked from a specified range. Frame Definition A set of field to control what kind of CAN frame to send out and what data it should contain. Frame type is selected from a select box. Possible frame types are 'CAN', 'CAN FD' and 'ERRORFRAME'. For a classic CAN frame it's possible to select if it should be a 'remote request frame'. For a CAN FD frame it's possible to select if 'bit rate switch' should be used. Both classic CAN and CAN FD frames can be sent out as single shot, no retransmission on collision. Frame data is defined by selecting message data length and by editing the message raw data by entering the value of each byte. Both the message data length and the message raw data can be randomized. Transmission Interval A set of fields to control the transmission interval. Constant interval: The same interval is used between each transmission. Random interval: Interval to use is picked by taking a random interval from a specified range. Scan interval: Interval to use is picked from a specified range. Number of Messages Specifies a fixed number of messages to be sent out or unlimited number of messages. Burst Size A set of fields to control the burst size, i.e. the number of messages to be sent out at every sample point. Constant burst size: The same number of messages are sent out at every sample point. Random burst size: Burst size to use is picked by taking a random value from a specified range.